| 8.30 |
 |
Registration & Coffee |
|
|
 |
| 9.00 |
|
Chairman's Opening Remarks |
|
Lars Kreye, Associate Director Aseptic Area 4, Boehringer Ingelheim .
|
|
 |
| 9.00 |
|
IMPLEMENTING A NEW SYRINGE FILLING LINE - RISKS AND TECHNICAL PITFALLS |
|
Impact on drug stability
- Time frame
- Points to consider
- Solutions
- Being productive
- Conclusion
Lars Kreye, Associate Director Aseptic Area 4, Boehringer Ingelheim .
|
|
 |
| 9.35 |
|
ENHANCING ADHESIVE POLYMERIZATION OF PRE ATTACHED NEEDLES FOR PREFILLED SYRINGES |
- Adhesive chemistry
- UV activation (photo-initiators)
- Materials compatibility (glass/steel)
- Dimensional compatibility
- OMPI case study / optimized process / next steps
- Results
Alessandro Morandotti, R&D Department, Stevanato Group .
Gabriele Peron, Marketing Manager, Stevanato Group - Glass Division.
|
|
 |
| 10.10 |
 |
Morning Coffee |
|
|
 |
| 10.40 |
|
CODING OF PREFILLED SYRINGES |
- Project drivers
- Requirements
- Technologies
- Solutions
Joern Koehler, Deputy Head of Liquid Vials & Prefilled Syringes, F.Hoffman-La Roche.
|
|
 |
| 11.15 |
|
HIGH SPEED INSPECTION OF PREFILLED SYRINGES |
|
A presentation of technical principles and advantages, quality parameters and new features in a CVT-machine
- Overview of inspections
- Syringe handling for inspection
- Maximising DR - minimising FRR
- Addressing potential problems
Gert Nielsen, Director, Chief Executive Officer, InnoScan.
|
|
 |
| 11.50 |
|
INNOVATIVE SYRINGE SOLUTIONS |
- Syringe system materials combination for WFI
- Tests and references
- Timepoints and storage conditions
- Results
Horst Koller, Manager Scientific Advisory, SCHOTT forma vitrum.
|
|
 |
| 12.25 |
 |
Networking Lunch |
|
|
 |
| 1.35 |
|
PRE-FILLED SYRINGE DEVELOPMENT |
- Design development phases
- Key drivers
- Product compatibility and approaches
Julien Tirefort, Packaging Projects Leader, Sanofi Pasteur.
|
|
 |
| 2.10 |
|
IMPACT ON DRUG DELIVERY DEVICES DEVELOPMENT |
- Current and future trends for drug delivery devices
- Does one solution fit all?
- System conception approach integrating prefilled and self-injection devices
Nicolas Bralet, Marketing Manager, Europe, BD Medical - Pharmaceutical Systems.
|
|
 |
| 2.45 |
|
ADVANCED ELASTOMERIC COMPONENTS FOR PFS |
- Considerations and functions
- Interaction potential
- Coating
Renaud Janssen, Technical Support Director, Helvoet Pharma.
|
|
 |
| 3.20 |
 |
Afternoon Tea |
|
|
 |
| 3.50 |
|
NEW PHYSICAL CONTAINER CLOSURE INTEGRITY TEST FOR PREFILLED SYRINGES BY ALTERATION OF DIN EN ISO 7886-1 |
- Overview on existing CCIT-methods for pre-filled syringes and cartridges
- Brief description of CCIT-test method according to DIN EN ISO 7886-1
- New CCIT approach by alteration of DIN EN ISO 7886-1
- Capability of altered DIN EN ISO 7886-1 method versus microbiological challenge test
- Advantages and restrictions of new CCIT method
Markus Hemminger, Head of Primary Packaging Development, Boehringer Ingelheim .
|
|
 |
| 4.25 |
|
CAN RIVA (ROBOTIC IV AUTOMATION) BE THE RIGHT SOLUTION FOR YOUR PRE-FILL BUSINESS? |
- RIVA introduction and capability
- ROI and financial considerations
- Implementation strategies
- Future development at Intelligent Hospital Systems
Jane Arnot, Vice President, Sales & Customer Support, Intelligent Hospital Systems.
|
|
 |
| 5.00 |
 |
Chairman’s Closing Remarks and Close of Day One |
|
|
|
 |
|  |